Tyco Flow Control Pacific

Search 

 
Goyen Dust Filter Cleaning Systems Applications Products Downloads Contact Us TES Home
Products : Precision Controller

 

Brochure Download:


Precision - Total Dust Collector Control System



The Goyen Precision series dust collector cleaning systems controller has a unique modular format that allows a simple Sequential Mode controller to be easily upgraded to Enhanced Differential Pressure Mode control, analog and digital I/O, and full SCADA and DCS integration.

Goyen's Precision controller grows with the demands of yours and your customer's business.

Description:

This new generation cleaning system controller is presented as an easily configurable master plus expansion card platform. The master controller has 10 on-board outputs, which may be expanded to 200 outputs total through the connection of up to nineteen 10 output expansion cards. All outputs feature individual push-button manual triggers and LED lights. The expansion cards are available with compact push-in terminals or large screw-terminal types.

Precision P1 - Continuous Control

The Continuous Control interface provides simple and dependable reverse pulse cleaning control on a time interval basis. Electrical actuation times range from 30 to 500ms and the between pulse pause time ranges from 1 to 999 seconds. Valves are pulsed sequentially.

Some other features include:

  • Automatic solenoid detection on start up.
  • Pulse counter.
  • Automatic solenoid failure detection
  • Count-down timer to next pulse
  • A visible indication of the next solenoid to pulse.
  • Manual solenoid triggers and individual output LEDs.

These features ease the product installation and diagnosis of cleaning system problems.

Precision P2 - Enhanced Demand Control

In addition to the features of the P1, the Enhanced Demand Control Interface provides sophisticated on-demand filter cleaning functions. The cleaning cycle is regulated by the differential pressure across the filters on the basis of high and low differential pressure limits, or on the basis of a trigger value and a % pressure drop desired.

Enhanced features include:

  • Display in a choice of measurement units.
  • Optional definition of minimum pulse rates while in demand mode (two speed cleaning).
  • A selection of pre-programmed cleaning patterns to minimise dust re-entrainment.
  • Filter precoating.
  • Blowdown (shut-down) cleaning cycles.

P-CTX - Voltage free contacts module

The contacts module allows the Precision system to interface easily to range of devices including programmable logic controllers, lights, push buttons, sirens and chart recorders. This is achieved through voltage free contacts and a 4-20mA differential pressure output. Functionality includes:

  • Alarm outputs
  • Pulsing indicators
  • Manual cycle trigger
  • Alarm reset inputs
  • One Auxilliary inpu (Eg. broken filter detector)

P-MOD - Modbus RTU network module

The P-MOD module allows the full integration of the Precision controller into SCADA / plant control networks. With all controller events accessible and each control output individually addressable, total distributed control system integration with particulate monitoring devices and process controls is possible.

For further information or hard copies of brochures, please contact us directly.

To view the various documents, you require Adobe Acrobat Reader installed.
Please download the latest reader via the following link.

 



10 Series Pulse Controller

 

The Goyen 10 Series Pulse Controller is an advanced microprocessor controller of the cleaning system in reverse pulse filters in pneumatic systems.

The 10 Series Pulse Controller can operate in the following modes:

  • Off
  • Continuous
  • Demand (Optional Accessory).

Features of the 10 Series Pulse Controller include:

  • Adjustable pulse on time to 1sec. Range 10 to 999ms.
  • Adjustable pause time to 1sec. Range 1 to 999 sec.
  • Microprocessor control eliminates drift.
  • Controlled accuracy of pulse and interval.
  • Pause in after cleaning option adjustable to 1sec. Range 1 to 99sec.
  • Number of cleaning cycles in shutdown adjustable to 1 sec. Range 1 to 99sec.
  • Fast set up.
  • Alarm options.
  • Self-diagnostic function.
  • Valve firing display.



  • 20 Series Pulse Controller - Operating Guide 420 KB
  • 20 Series Pulse Controller - Technical Details 143 KB
  • 20 Series Pulse Controller

     

    The Goyen 20 Series Pulse Controller is an advanced microprocessor controller of the cleaning system in reverse pulse filters in pneumatic systems.

    The 20 Series Pulse Controller can operate in the following modes:

    • Off
    • Manual
    • Automatic

    In AUTOMATIC mode, sequential cleaning is initiated only when the differential pressure (DP) across the filter reaches a predetermined level. Once the DP is reduced to an acceptable level, sequential cleaning ceases.

    Features of the 20 Series Pulse Controller include:

    • Adjustable pulse on time to 1m sec. Range 10 to 999ms.
    • Adjustable pause time to 1sec. Range 1 to 999 sec.
    • Microprocessor control eliminates drift.
    • Pause in after cleaning option adjustable to 1sec. Range 1 to 999sec.
    • Fast set up.
    • Number of after cleaning cycles adjustable from 0-99.
    • Automatic shutdown from integral Delta P switch (no wiring).
    • Alarm options.
    • Fast set up
    • Valve diagnostic display.
    • Low air pressure option
    • Self-diagnostic function



     



  • 100 Series Pulse Controller - Operating Guide 434 KB
  • 100 Series Pulse Controller - Technical Details 163 KB
  •  

    100 Series Pulse Controller

     

    The Goyen 100 Series Pulse Controller is an advanced microprocessor controller of the cleaning system in reverse pulse filters in pneumatic systems.

    The 100 Series Pulse Controller can operate in the following modes:

    • Off
    • Continuous
    • Demand (Optional Accessory)

    Features of the 100 Series Pulse Controller include:

    • Adjustable pulse on time to 1sec. Range 10 to 999ms.
    • Adjustable pause time to 1sec. Range 1 to 999sec.
    • Microprocessor control eliminates drift
    • Controlled accuracy of pulse interval.
    • Pause after cleaning option adjustable to 1sec. Range 1 to 99sec.
    • Number of cleaning cycles in shutdown adjustable to 1sec. Range 1 to 99sec.
    • Fast set up.
    • Alarm options.
    • Low air pressure warning.
    • Self-diagnostic function.
    • Valve firing display.

     



  • 200 Series Pulse Controller - Operating Guide 689 KB
  • 200 Series Pulse Controller - Technical Details 71 KB
  • 200 Series Pulse Controller

     

    The Goyen 200 Series Pulse Controller is an advanced microprocessor controller of the cleaning system in reverse pulse filters in pneumatic systems.

    The 200 Series Pulse Controller can operate in the following modes:

    • Off
    • Manual
    • Automatic

    In AUTOMATIC mode, sequential cleaning is initiated only when the differential pressure (DP) across the filter reaches a predetermined level. Once the DP is reduced to an acceptable level, sequential cleaning ceases.

    Features of the 20 Series Pulse Controller include:

    • Adjustable pulse on time to 1m sec. Range 10 to 999ms.
    • Adjustable pause time to 1sec. Range 1 to 999 sec.
    • Microprocessor control eliminates drift.
    • Pause in after cleaning option adjustable to 1sec. Range 1 to 99sec.
    • Fast set up.
    • Number of after cleaning cycles adjustable from 0-99.
    • Automatic shutdown from integral Delta P switch (no wiring).
    • Alarm options.
    • Fast set up
    • Valve diagnostic display.
    • Low air pressure option.
    • Self-diagnostic function.
    • Valve firing display.
    • Display of current differential pressure.


     

    GC3000 Series Cleaning System Controller

    (USA ONLY)

    The Goyen Go-Co GC3000 series cleaning system controller was designed to satisfy the requirement for reliable 'demand' cleaning. The unit has two major components:

    • A differential pressure gauge with adjustable high and low set points, and
    • Integral solid state relay electronics, a programmable, microprocessor based timer card.

    Three modes of operation can be programmed; 'off', 'continuous' or 'demand'. Off is primarily used to isolate the system during maintenance. Continuous mode sequentially switches valves on and off. Demand mode is when the cleaning cycle is initiated by the pressure drop across the filter.

    In practice demand cleaning reduces the number of cleaning pulses in a given period of time resulting in extended bag life, reduced compressed air consumption, longer valve life, lower emissions and less service downtime.



    TBD Series Digital Timer

    (USA ONLY)

    Goyen's digital timer is designed to control the frequency and duration of the cleaning pulse in a Reverse Pulse Filter. It does this by providing a timed sequential signal to the pilot solenoid valve.

    The Goyen digital timer may also be used in any application where sequential timing is required.

    Features include:

    • Microprocessor controlled.
    • Digital display for ease of setting and checking.
    • 4-48 outputs
    • All circuits include input surge suppression.
    • Automatic blowdown allows the timer to complete up to 25 cycles after the dust collector is turned off.

     